ITCertKing's HP HP0-500 exam training materials is no other sites in the world can match. Of course, this is not only the problem of quality, it goes without saying that our quality is certainly the best. More important is that ITCertKing's exam training materials is applicable to all the IT exam. So the website of ITCertKing can get the attention of a lot of candidates. They believe and rely on us. It is also embodied the strength of our ITCertKing site. The strength of ITCertKing is embodied in it. Our exam training materials could make you not help recommend to your friends after you buy it. Because it's really a great help to you.
HP certification HP0-500 exam is a test of IT professional knowledge. ITCertKing is a website which can help you quickly pass HP certification HP0-500 exams. In order to pass HP certification HP0-500 exam, many people who attend HP certification HP0-500 exam have spent a lot of time and effort, or spend a lot of money to participate in the cram school. ITCertKing is able to let you need to spend less time, money and effort to prepare for HP certification HP0-500 exam, which will offer you a targeted training. You only need about 20 hours training to pass the exam successfully.
About the materials that relate to HP HP0-500 exam, many websites can offer the exam materials. But these websites can't guarantee the quality of the exam dumps, meanwhile when you fail the exam, they can't also give you FULL REFUND guarantee. Compared with common reference materials, ITCertKing HP HP0-500 certification training materials is the tool that worth your use. With the help of ITCertKing HP HP0-500 real questions and answers, you can absolutely well prepare for the exam and pass the exam with ease. If you want to great development in IT industry, you need to take IT certification exam. If you want to pass your IT certification test successfully, it is necessary for you to use ITCertKing exam dumps.
We are committed to using ITCertKing HP HP0-500 exam training materials, we can ensure that you pass the exam on your first attempt. If you are ready to take the exam, and then use our ITCertKing HP HP0-500 exam training materials, we guarantee that you can pass it. If you do not pass the exam, we can give you a refund of the full cost of the materials purchased, or free to send you another product of same value.
Exam Code: HP0-500
Exam Name: HP (HP ProLiant Server Maintenance)
One year free update, No help, Full refund!
Total Q&A: 200 Questions and Answers
Last Update: 2014-02-14
HP0-500 Free Demo Download: http://www.itcertking.com/HP0-500_exam.html
NO.1 .Which Compaq server component is covered under prefailure warranty?
A. DIMM memory
A. hard disk controller
B. recovery server option
C. network interface controller
Answer: A
HP HP0-500 HP0-500 HP0-500
NO.2 .What is used to disable a Compaq server serial port?
A. Compaq Insight Manager
B. System Board Switch
C. System Configuration Utility
D. Nothing, as it is disabled by default
Answer: C
HP HP0-500 dumps HP0-500 pdf HP0-500 demo HP0-500 answers real questions
NO.3 .Where should the server Feature Board be installed in Compaq servers?
A. A designated slot
B. Any PCI 64-bit slot
C. Any extended slot
D. An EISA slot
Answer: A
HP test answers HP0-500 practice test HP0-500 HP0-500 test questions
NO.4 .After a field engineer adds a second array controller to the server, the operating system does not boot .
What is the likely cause of the problem?
A. incorrect jumper settings
B. incorrect slot order
C. array controller boot order D. interrupt conflicts
Answer: C
HP HP0-500 practice test HP0-500 pdf HP0-500 braindump HP0-500
NO.5 .What action is recommended if the Server Health Driver consistently reports a correctable memory
error in the same location?
A. Run ERASE utility to clear the location.
B. Schedule downtime and replace memory.
C. This is normal and can be ignored.
D. Mark "repaired" in Insight Manager.
Answer: B
HP HP0-500 HP0-500 demo HP0-500 certification training HP0-500 HP0-500
NO.6 .Which utility is assists in planning and configuring Compaq racks?
A. RackManager
B. RackAssistant
C. RackIntegrator
D. RackBuilder Pro
Answer: D
HP HP0-500 original questions HP0-500 pdf HP0-500 practice test HP0-500
NO.7 .What is the first required action to safely remove an adapter from a Compaq PCI hot-pluggable slot?
A. Just remove the card.
B. Power down the slot to remove the card.
C. Power down the server to remove the card.
D. Install the new card in another slot.
Answer: B
HP HP0-500 questions HP0-500 certification training HP0-500
NO.8 .What can Compaq Diagnostics reliably test?
A. Compaq Insight Manager (CIM) agents
B. system ROM BIOS compatibility
C. DAT tape drive read/write function
D. non-Compaq SCSI controller
Answer: C
HP original questions HP0-500 test answers HP0-500 original questions
NO.9 .A defective processor is replaced in a Compaq server. The 212 "System Processor Failed" POST
error will not go away. What action can be performed?
A. Erase NVRAM to clear the Health Log.
B. Run Diagnostics on memory.
C. Replace hot-pluggable power supply.
D. Replace Memory Expansion Board.
Answer: A
HP HP0-500 test HP0-500 pdf HP0-500 demo
NO.10 .What is the advantage of having an online spare as part of a SMART array configuration?
A. The drive can be used for temporary data storage until another drive fails.
B. The array will not lose its fault tolerance in case of a single drive failure.
C. You always have a spare drive available to physically put in place of a failed drive without having to
order a spare drive.
D. You can load balance across the array.
Answer: B
HP HP0-500 HP0-500 test questions HP0-500 HP0-500 exam HP0-500
NO.11 .What problem is indicated if the server powers up with no video and an audible POST error?
A. memory module not seated
B. monitor signal cable not connected
C. intermittent memory parity errors
D. monitor in power saver mode
Answer: A
HP HP0-500 answers real questions HP0-500 braindump HP0-500
NO.12 .Which network interface controller configuration can support redundant NICs?
A. one dual-port fast Ethernet network controller
B. one 16/4 token ring network controller connected to a managed hub
C. one fast Ethernet network controller connected to a second server
D. one fast Ethernet network controller connected to a router
Answer: A
HP HP0-500 braindump HP0-500 certification HP0-500 test answers
NO.13 .On a ProLiant 450 MHz processor server, Level 2 cache is logging errors. Which item should be
replaced?
A. Cache Memory Stick
B. System I/O Board
C. CPU/Processor Module
D. Riser Card
Answer: C
HP dumps HP0-500 test HP0-500 certification
NO.14 .Which action is required to safely replace non hot-pluggable components in servers with redundant
hot-pluggable power supplies?
A. Depress server On/Off switch from front panel.
B. Ensure DC LED indicator on the hot-pluggable power supply is inactive.
C. Remove AC power cord from the primary hot-pluggable power supply.
D. Remove AC power cords from all hot-pluggable power supplies.
Answer: D
HP HP0-500 questions HP0-500 exam dumps HP0-500 certification training
NO.15 .A hard drive fails on a system with an on-line spare. When is it recommended that the failed drive be
replaced?
A. upon discovery of the failure
B. upon completion of rebuild of on-line spare
C. not needed, failed drive will perform self-repair
D. any time before rebuild of online spare is complete
Answer: B
HP certification training HP0-500 HP0-500 HP0-500 HP0-500 original questions
NO.16 .While running Diagnostics on your ProLiant server, you receive an error code: 6092. What should you
do?
A. Replace network card.
B. Replace disk controller.
C. Connect external loopback cable.
D. Place network card in a different slot.
Answer: C
HP certification training HP0-500 HP0-500 HP0-500
NO.17 .What is the likely cause of rack instability?
A. more than one component simultaneously extended
B. UPS installed at the bottom of the rack
C. side panels not installed
D. missing blanking panels
Answer: A
HP test HP0-500 test answers HP0-500 certification training HP0-500 HP0-500 test
NO.18 .When servicing a customer's system, what is the proper sequence to remove power to the server and
any external storage subsystems?
A. external storage systems first, then server
B. server first, then the external storage systems
C. UPS, then the server
D. external storage first, then the UPS
Answer: B
HP HP0-500 certification training HP0-500 exam dumps HP0-500 HP0-500
NO.19 .Which resources could be used to help isolate correctable memory errors?
A. SSD and DAAD
B. ACU and SmartStart
C. Server Health Logs and Integrated Management Log
D. QRG (Quick Reference Guide) and Inspect
Answer: C
HP demo HP0-500 exam dumps HP0-500 original questions HP0-500 pdf
NO.20 .Which Compaq utility is used to configure Online Spare memory?
A. Rapid Raid Utility
B. Raid Builder for AMP
C. ROM-based Setup Utility
D. SmartStart
Answer: C
HP demo HP0-500 HP0-500 practice test
NO.21 .Which product reports prefailure on all Compaq SMART hard drives?
A. CIM
B. RBSU C. ACU D. SCU
Answer: A
HP exam simulations HP0-500 study guide HP0-500
NO.22 .How is a redundant Xeon server PPM identified?
A. one processor installed
B. two processors installed
C. fully populated PPM circuit board
D. half populated PPM circuit board
Answer: C
HP braindump HP0-500 exam dumps HP0-500 HP0-500 test
NO.23 .What enables remote server management and control regardless of the operating system or condition
of the server?
A. CIM (Compaq Insight Manager)
B. SCU (System Configuration Utility)
C. Remote Utilities (from system Diagnostics menu)
D. RILOE (Remote Insight Light Out Edition option)
Answer: D
HP braindump HP0-500 test questions HP0-500 braindump HP0-500 HP0-500 pdf
NO.24 Which component failure will cause a Compaq server to reset but not power up?
A. IMD
B. PPM
C. DIMM
D. CPU
Answer: B
HP HP0-500 demo HP0-500
NO.25 .Which diagnostic mode tests individual components of a server?
A. Intermediate
B. Automatic
C. QuickCheck
D. Prompted
Answer: D
HP test answers HP0-500 HP0-500 HP0-500 test answers HP0-500 HP0-500 study guide
NO.26 .What is the available array space after grouping six 4GB hard drives using Advanced Data Guarding?
A. 12GB
B. 16GB
C. 20GB
D. 24GB
Answer: B
HP HP0-500 HP0-500 questions HP0-500
NO.27 .What capability do fans have in some hot-pluggable power supplies?
A. variable RPM, depending on thermal sensor readings
B. hot plug fan replacement
C. dual-power inputs for redundancy
D. redundant power supply fans
Answer: A
HP test answers HP0-500 HP0-500 certification HP0-500 certification
NO.28 .What are the best sources for the latest versions of Rompaqs and Softpaqs? Select two.
A. Compaq ResourcePaq
B. SmartStart
C. HP/Compaq website
D. QuickFind2000
E. OS ServicePaq
Answer: B,C
HP braindump HP0-500 HP0-500 HP0-500 practice test
NO.29 .What do Compaq hot-pluggable power supplies have that traditional power supplies do not?
A. higher current
B. higher voltage
C. microcontroller Self-Test
D. power Monitor Port
Answer: C
HP HP0-500 HP0-500 test questions HP0-500
NO.30 .Which step must be performed when upgrading a customer's ProLiant server from a Pentium II Xeon
to Pentium III Xeon processor?
A. Flash ROM before replacing processors.
B. Ensure all processors have the same frequency and cache size.
C. Mix cache sizes in pairs for sockets 1 and 3.
D. Upgrade terminator boards for all four sockets.
Answer: A
HP dumps HP0-500 HP0-500 test questions
ITCertKing offer the latest NS0-145 exam material and high-quality C_TSCM52_66 pdf questions & answers. Our 1Z0-409 VCE testing engine and 00M-653 study guide can help you pass the real exam. High-quality E20-018 dumps training materials can 100% guarantee you pass the exam faster and easier. Pass the exam to obtain certification is so simple.
Article Link: http://www.itcertking.com/HP0-500_exam.html
没有评论:
发表评论